333

The event menu includes the following options:

/cfg/sys/adm/snmp/event

followed by:

addmonitor [ <options> ] -b

<name> <OID> <op> <value>

Adds a boolean monitor and trigger as
defined in the DISMAN-EVENT-MIB.

Valid

<options>

are:

-c <comment>

—adds a comment

-f <frequency>

—the sampling

interval, in seconds. The default is 600
(10 minutes).

-o <OID>

—additional objects to send

in the event

-e <EventName>

—the name of a

notification event

-d <OID>

—the delta discontinuity OID

-D timeTicks|timeStamp|dateAnd

Time

—the delta discontinuity type

Other parameters are:

name

—a unique name you assign to

the monitor, for identification

OID

—the object identifier (or symbolic

name) to monitor

op

—the operator. Valid options are:

!= (not equals), == (equals), <= (less
than or equal to), >= (greater than or
equal to), < (less than), > (greater than)

value

—an integer indicating the value

against which the operation will be
performed