Maintaining and managing the system

/maint

followed by:

dumplogs

<protocol> <host

name or IP address

of server>

<filename on

server> <collect

info from all

cluster host?>

Collects system log file information and sends it
to a file on the specified file exchange server. The
information can then be used for technical support
purposes. You are prompted to provide the following
parameters if you do not specify them in the command:

protocol

is the export protocol. Options are

tftp|ftp|sftp

. The default is

tftp

.

server

is the host name or IP address of the file

exchange server.

filename

is the name of the destination log file

on the file exchange server. The file is in gzip
compressed tar format.

all-isds?

specifies whether the information is to

be collected from all Nortel SNAS devices in the
cluster or only from the device to which you are
connected. Valid options are

y

(= yes, all) or

n

(=

no, single).
If you specify

n

(= no) and you are connected to

the MIP, information will be collected for the Nortel
SNAS device currently in control of the MIP.

for FTP and SFTP, user name and password.

The file sent to the file exchange server does not
contain any sensitive information related to the system
configuration, such as private keys.

dumpstats

<protocol> <host

name or IP address

of server>

<filename on

server> <collect

info from all

cluster host?>

Collects current system internal status information and
sends it to a file on the specified file exchange server.
The information can then be used for technical support
purposes. You are prompted to provide the following
parameters if you do not specify them in the command:

protocol

is the export protocol. Options are

tftp|ftp|sftp

. The default is

tftp

.

server

is the host name or IP address of the file

exchange server.

filename

is the name of the destination file on the

file exchange server. The file is in gzip compressed
tar format.

all-isds?

specifies whether the information is to

be collected from all Nortel SNAS devices in the
cluster or only from the device to which you are

Nortel Secure Network Access Switch