Configuring the nortel snas pvip subnet, Creating port-based vlans, Configuring the voip vlans – Nortel Networks 5500 series User Manual

Page 396: Configuring the red, yellow, and green vlans, Configuring the login domain controller filters, Configuring the nsna ports

Advertising
background image

396

Configuration example

5510-48T(config)# ssh download-auth-key address

10.20.20.20 key-name sac_key.1.pub

5510-48T(config)# ssh

Configuring the Nortel SNAS pVIP subnet

5510-48T(config)# nsna nsnas 10.40.40.0/24

Creating port-based VLANs

5510-48T(config)# vlan create 210 type port

5510-48T(config)# vlan create 220 type port

5510-48T(config)# vlan create 230 type port

5510-48T(config)# vlan create 240 type port

Configuring the VoIP VLANs

5510-48T(config)# nsna vlan 240 color voip

Configuring the Red, Yellow, and Green VLANs

5510-48T(config)# nsna vlan 210 color red filter red

5510-48T(config)# nsna vlan 220 color yellow filter yellow

yellow-subnet 10.120.120.0/24

5510-48T(config)# nsna vlan 230 color green filter green

Configuring the login domain controller filters

ATTENTION

This step is optional.

The PC client must be able to access the login domain controller you configure
(that is, clients using the login domain controller must be able to ping that
controller).

5510-48T(config)# qos nsna classifier name RED dst-ip

10.200.2.12/32 ethertype 0x0800 drop-action disable block

wins-prim-sec eval-order 70

5510-48T(config)# qos nsna classifier name RED dst-ip

10.200.224.184/32 ethertype 0x0800 drop-action disable

block wins-prim-sec eval-order 71

Configuring the NSNA ports

Add the uplink port:

5510-48T(config)# interface fastEthernet 20

5510-48T(config-if)# nsna uplink vlans 210,220,230,240

5510-48T(config-if)# exit

Nortel Secure Network Access Switch

Using the Command Line Interface

NN47230-100

03.01

Standard

28 July 2008

Copyright © 2007, 2008 Nortel Networks

.

Advertising