6.4.2 Instantaneous value measurement -Over-range / Bar indication KEW6310

6.21

KEW6310

6.4.2 Over-range / Bar indication

Check the followings.

WARNING


● When the over-range indication appears on the maximum chosen range, this means that the input exceeds

the maximum allowable input for the instrument. Never apply such an input to the instrument.

● When a measured value exceeds the maximum allowable input, the use of VT/CT’s is recommended.

Refer to “5-3 VT/ CT“ in this manual and follow the instruction

CAUTION


● When over-range indication appears on the screen, calculations are still performed. However their accuracy

may not be guaranteed.

Over-range indication

A message “OL” is displayed when measured items exceed following conditions.

Voltage : Voltage Range x VT ratio x 120%

e.g. Voltage Range : 300V, VT ratio : 1 => 360.0V

Current : Current Range x CT ratio x 120%

e.g. Current Range : 200A, CT ratio : 2 => 480.0A

Power

: Power x VT ratio x CT ratio x 120% e.g. Power : 60kW, VT ratio : 1, CT ratio : 2 => 144.0kW

OL mark is displayed.