background image

4.2.1 Basic Setting KEW6310

4.17

KEW6310

Setting for Filter


Lowpass filter activate to cut frequencies in higher harmonic band when set the Filter function “ON”.
(Cutoff frequency : approx 160Hz)

Filter

Available (ON⇔OFF)

Not available (------)

Wiring

1P3W x 1+2A 3,4ch

3P3W x 1+2A 3,4ch

3P4W x 1+1A 4ch

4A

Clamp Sensor

8141/42/43/46/47/48

8128/27/26/25/24/29

* Default value (or after system reset) : ----- or OFF
* Bar “------“ is displayed for the Filter other than listed above, and a setting cannot be made.

1

Press the

Cursor

Keys and select [Filter], and then press the

ENTER

Key.

2

Press the

Cursor

Keys and select “ON” or “OFF”, and then press the

ENTER

Key.

3

Press the

Cursor

Keys and select ON / OFF for the other Chs, and make settings in the

same

way.

Drop down list appears.

Incapable of selecting ON/OFF

depending on the connected Sensors.

Selected Filter setting (ON or OFF) is displayed.