2 getting power from measured lines – KYORITSU 6310 Instruction Manual User Manual

Page 278

Advertising
background image

14.2 Getting power from measured line KEW6310

14.3

KEW6310

14.2 Getting power from measured lines


When there is difficulties in getting power from an outlet, KEW6310 operates with powers on the
measured line by using Voltage test leads with Power supply adapter MODEL8312.


Connect the Adapter according to following procedure.

1

Confirm that the Adapter is off.

2

Connect the Plug of the Adapter to VN and V1

terminals on KEW6310/6300 and Power Plug to

the Power connector respectively.

3

Connect the Voltage test leads to VN and V1

terminals

of

the

Adapter.

4

Connect the Alligator clips of the Voltage test

leads to the circuit under test.

5 Power

on

the

Adapter.

6

Power on KEW6310/ 6300.

* Reversed procedure is applied to remove the

Adapter from KEW6310/ 6300.

Fuse rating : AC500mA/ 600V,
Fast acting, Φ6.3 x 32mm







For further details, refer to the Instruction manual for MODEL 8312.


1

2

3

4

5

6

Advertising