11.3.2 Power quality – Measuring procedure (Transient measurement) KEW6310
11.13
KEW6310
Timing of data recording
<
Recording at event occurrence>
<
Recording at every interval>
* Function available with ver2.00 or later.
Avg,max and min* values within
each interval are recorded.
※
Inst value : max value of 10,000 data obtained by sampling at 100us
1sec before the preset interval comes
Avg value : Avg of inst values obtained in the preset inst interval
Max value : Max inst values obtained in the preset inst interval
Min value : Min inst values obtained in the preset inst interval
Interval Interval
201 data pts
recorded
Past 100
Data pts
Next 100
Data pts
Trigger
Threshold
110%
start
Peak(max)
100%
reference Voltage