Quick Start

This section is provided to help experienced users quickly start using the
adapter. If you are unsure how to complete a step, refer to the referenced
chapter.

Step Action

See

1

Review the safety precautions for the adapter.

Throughout this manual

2

Verify that the PowerFlex drive is properly installed.

Drive User Manual

3

Install the adapter.
a. Verify that the PowerFlex drive is not powered.
b. Connect the adapter to the drive with the Internal Interface

cable.

c. Use the captive screws to secure and ground the adapter to

the drive.

d. Connect the adapter to the network with a DeviceNet cable.
NOTE: When installing the adapter in either of the following

products, see the listed publication for instructions:
• DPI External Comms Kit—see the 20-XCOMM-DC-BASE

Installation Instructions, publication 20COMM-IN001, supplied

with the kit.

• PowerFlex 750-Series drive—see the 20-750-20COMM and

20-750-20COMM-F1 Communication Carrier Cards

Installation Instructions, publication 750COM-IN001, supplied

with the card.

PowerFlex 7-Class DPI

Network Communication

Adapter Installation

Instructions (publication

20COMM-IN004) and

Chapter 2

,

Installing the Adapter

4

Apply power to the adapter.
a. Verify that the adapter is installed correctly.

The adapter receives power from the drive.

b. Apply power to the drive.

The status indicators should be green. If they flash red, there

is a problem. See

Chapter 7

,

Troubleshooting

.

c. Configure and verify key drive parameters.

Chapter 2

,

Installing the Adapter

5

Configure the adapter for your application.

Set adapter parameters for the following functions as required by

your application:

• Node address and data rate (when Data Rate switch is set to

‘PGM’)

• I/O configuration

• Change of State, Cyclic, or Polled I/O data exchange

• Master-Slave or Peer-to-Peer hierarchy

• Fault actions

Chapter 3

,

Configuring the Adapter

6

Configure the controller to communicate with the adapter.

Use configuration tools, such as RSNetWorx for DeviceNet

software and RSLogix software, to configure the master on the

network to recognize the adapter and drive.

Chapter 4

,

Configuring the I/O

7

Create a ladder logic program.

Use a controller configuration tool, such as RSLogix software, to

create a ladder logic program that enables you to do the

following:

• Control the connected drive, via the adapter, by using I/O.

• Monitor or configure the drive using explicit messages.

Chapter 5

,

Using the I/O
Chapter 6

,

Using Explicit

Messaging

Advertising