Setting datalinks in the drive (optional) – Rockwell Automation 20-COMM-D DeviceNet Adapter Series B FRN 2.xxx User Manual

Page 56

Advertising
background image

4-14

Configuring the I/O

20-COMM-D DeviceNet Adapter User Manual

Publication 20COMM-UM002G-EN-P

15. Click AutoMap to map the drive output image to the 1756-DNB

scanner as shown in this example below.

16. Click OK.

If the Scanner Configuration Applet appears and asks to download these
settings to the 1756-DNB scanner, click Yes.

17. Click File > Save.

If this is the first time you saved the project, the Save As dialog box
appears.

a. Navigate to a folder.

b. Type a file name.

c. Click Save to save the configuration as a file on your computer.

Setting Datalinks in the Drive (Optional)

After configuring the 1756-DNB scanner, the drive Datalinks must be set to
parameters that are appropriate for your application. (This also enables the
DeviceNet Tag Generator to create descriptive controller tags for your
RSLogix 5000 project.)

1. Use any of the drive configuration tools or RSNetWorx for DeviceNet

software to set the Datalinks in the drive.

For this example, RSNetWorx for DeviceNet software and the
following Datalink values were used.

TIP: If your RSLogix 5000 project requires a different starting DWord
(double word, 32-bit) than the default value of 0 for the drive output
image, set the Start DWord field to the appropriate value.