Rockwell Automation 20-COMM-D DeviceNet Adapter Series B FRN 2.xxx User Manual
Page 52

4-10
Configuring the I/O
20-COMM-D DeviceNet Adapter User Manual
Publication 20COMM-UM002G-EN-P
11. Click the Scanlist tab to begin the drive I/O configuration.
The Available Devices box shows devices that are presently on the
DeviceNet network but are not yet configured. The Scanlist box shows
devices that are presently on the DeviceNet network and are configured.
a. For this example, uncheck the Automap on Add box.
b. Select the PowerFlex 70 EC drive in the Available Devices box.
c. Click ‘>’ to move the PowerFlex 70 EC drive to the Scanlist box.
TIP: The Automap on Add box is checked by default and allows
RSNetWorx for DeviceNet software to automatically map the drive I/O
into the scanner in the next available registers. The mapping is based on
the minimum I/O requirements (4 bytes for input and 4 bytes for output)
that the scanner obtains from the drive EDS file.
Box
Setting
Node Active
Activates/deactivates the scanlist in the 1756-DNB scanner for the
selected device. For this example, keep the box checked.
Device Type
These Electronic Key category check boxes select how specific the
device in the scanlist must be for the 1756-DNB scanner to match its
compatibility for I/O operation. The more boxes that are checked, the
more specific the device must be to operate. For this example, keep
the default boxes (Device Type, Vendor, and Product Code) checked.
Vendor
Product Code
Major Revision