4-16

Configuring the I/O

20-COMM-D DeviceNet Adapter User Manual

Publication 20COMM-UM002G-EN-P

4. With the parameter list showing, set the various Data In and Data Out

parameters.

In this example, the Datalinks are set to the values shown in

Table 4.D

.

5. Click OK.

If the EDS Editor dialog box appears, asking to download the
configuration to the drive from the software configuration, click Yes.
After the download is completed, the PowerFlex 70 EC Drive Properties
screen closes.

Using the DeviceNet Tag Generator to Create Descriptive Controller

Tags (Optional)

DeviceNet controller tags are non-descriptive for I/O configurations in
RSLogix 5000 projects. However, the DeviceNet Tag Generator, a free
Rockwell software tool, can generate descriptive controller tags for basic
control I/O words (Logic Command/Status and Reference/Feedback) and
Datalinks. Additionally, Datalinks automatically take the name of the drive
parameter to which they are assigned.

Important: The DeviceNet Tag Generator will only create correct tag

names if the EDS file being used is downloaded from the
website (see

Downloading the EDS File from Rockwell

Automation Website on page 4-8

)—not created from the

network. Also, the DeviceNet Tag Generator is not supported
on PowerFlex 700S and PowerFlex 750-Series drives.

To use the DeviceNet Tag Generator, the following compatible
software is required.

The DeviceNet Tag Generator is only recommended when:

• A new DeviceNet system and/or new drive is being installed.
• Migration to required software is acceptable for an existing system or

application.

The free DeviceNet Tag Generator software is available for download on
the Rockwell Automation website

http://www.rockwellautomation.com/

support/webupdates

.

1. Close the RSNetWorx for DeviceNet software if it is running.

2. Verify that the controller is in Rem Prog or Program Mode, and that the

RSLogix 5000 project is offline with the controller.

Software

Required Version

RSNetWorx for DeviceNet

7.00 (or later)

RSLinx Classic

2.51 (or later)

RSLogix 5000

13.00 (or later)