Logic Command/Status Words

20-COMM-D DeviceNet Adapter User Manual

Publication 20COMM-UM002G-EN-P

Logic Status Word

Logic Bits
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Status

Description

x

Active

0 = Not Active

1 = Active

x

Running

0 = Not Running

1 = Running

x

Command

Direction

0 = Reverse

1 = Forward

x

Actual Direction

0 = Reverse

1 = Forward

x

Accel

0 = Not Accelerating

1 = Accelerating

x

Decel

0 = Not Decelerating

1 = Decelerating

x

Jogging

0 = Not Jogging

1 = Jogging

x

Fault

0 = No Fault (Par. 323, 324, 325)

1 = Fault

x

Alarm

0 = No Alarm (Par. 326, 327, 328)

1 = Alarm

x

Flash Mode

0 = Not in Flash Mode

1 = In Flash Mode

x

Run Ready

0 = Not Ready to Run (Par. 156)

1 = Ready to Run

x

At Limit

(1)

0 = Not At Limit (Par. 304)

1 = At Limit

x

Tach Loss Sw

0 = Not Tach Loss Sw

1 = Tach Loss Sw

x

At Zero Spd

0 = Not At Zero Speed

1 = At Zero Speed

x

At Setpt Spd

0 = Not At Setpoint Speed

1= At Setpoint Speed

x

Enable

0 = Not Enabled

1 = Enabled

(1)

See Parameter 304 - [Limit Status] in the PowerFlex 700S drive User Manual for a description of the limit status conditions.