11 - replacement parts, Replacement cables and connectors, Chapter 11 – Rockwell Automation 1747-L5xx SLC 500 Modular Hardware Style User Manual User Manual

Page 169: Replacement parts, Chapter

Advertising
background image

169

Publication 1747-UM011G-EN-P - June 2008

Chapter

11

Replacement Parts

This chapter provides a list of replacement parts and a list of
replacement terminal blocks for your SLC 500 controller.

Replacement Cables and
Connectors

Description

Cat. No.

Chassis Interconnect Cable - The 1746-C7 cable is a 152.4 mm (6 in.) ribbon cable used when linking modular hardware

style chassis up to 152.4 mm (6 in.) apart in an enclosure.

1746-C7

Chassis Interconnect Cable - The 1746-C9 cable is a 914.4 mm (36 in.) cable used when linking modular hardware style

chassis from 152.4 mm (6 in.) up to 914.4 mm (36 in.) apart in an enclosure.

1746-C9

Chassis Interconnect Cable - The 1746-C16 cable is a 1.27m (50 in.) cable used when linking modular hardware style

chassis from 0.914m (36 in.) up to 1.27m (50 in.) apart in an enclosure. This is the longest chassis interconnect cable

recommended by Allen-Bradley.

1746-C16

32 Point Mating Connector - This connector is used for terminating a user-made cable. It is compatible with the DIN

RAIL mountable terminal block interface module, catalog number 1492-IFM40x (used with 32-point I/O modules).

1746-N3

Replacement Processor to Peripheral Programming/Communication Cable - This 1.8 m (6 ft) cable is used to connect

the interface converter to the SLC 500 controller when using personal computer interface software. This cable is also

used to connect the Hand-held Terminal to the SLC 500 controller and to connect the Data Table Access Module to the

SLC 500 controller.

1747-C10

Replacement Processor to Isolated Link Coupler Cable - This 304.8 mm (12 in.) cable is used to connect the SLC 500

controller to the isolated link coupler.

1747-C11

Communication Module to Isolated Link Coupler Cable - This 914.4 mm (36 in.) cable is used to connect communication

modules (for example, 1746-BAS, 1747-KE, and 1747-UIC interface) to the isolated link coupler. The isolated link

coupler must be powered by an external power supply or connected to a device with a 1747-C10 or 1747-C11 cable.

1747-C13

Replacement Processor to Peripheral Programming/Communication Cable - This 6.09 m (20 ft) cable is used to connect

the interface converter to the SLC 500 controller when using personal computer interface software. This cable is used

to connect the Data Table Access Module to the SLC 500 controller.

1747-C20

SLC 5/03, SLC 5/04, and SLC 5/05 RS-232 Programmer Cable - This 3.96 m (12 ft) cable has two 9-pin DTE connectors

and is used to connect the SLC processor RS-232 channel (channel 0) to a personal computer serial port.

1747-CP3

SLC 5/03, SLC 5/04, and SLC 5/05 Communication Cable - This 45 cm (17.7 in.) cable has two 9-pin DTE connectors and

is used to connect the SLC processor RS-232 channel (channel 0) to port 1 of the 1761-NET-AIC advanced interface

converter.

1761-CBL-AC00

SLC 5/03, SLC 5/04, and SLC 5/05 Communication Cable - This 2 m (6.5 in.) cable has a 9-pin DTE and an 8-pin mini

DIN connector and is used to connect the SLC processor RS-232 channel (channel 0) to port 2 of the 1761-NET-AIC

advanced interface converter.

1761-CBL-PM02

SLC 5/03, SLC 5/04, and SLC 5/05 Communication Cable - This 45 cm (17.7 in.) cable has a 9-pin DTE and an 8-pin mini

DIN connector and is used to connect the SLC processor RS-232 channel (channel 0) to port 2 of the 1761-NET-AIC

advanced interface converter.

1761-CBL-AP00

Advertising