Load initial configuration values chapter 7 – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual

Page 104

Advertising
background image

Enter Your Values Here

Load Initial Configuration Values

Chapter 7

7-23

Worksheet 7ĆJ (continued)
Second Clamp Open Configuration Block (SOC)

Control Word ProĆSet 600 Addr. Value

Description

Units

SOC05

N43:361

1000

Minimum ERC PercentageĆĆVelocity

Percent

8

SOC06

N43:362

1000

Minimum ERC PercentageĆĆPressure

Percent

8

SOC08

N43:364

0

Profile Watchdog Timer Preset

Time

1

SOC09

N43:365

*

Output #1 SetĆOutput Value during Profile

Percent Signal Output

3

SOC10

N43:366

*

Output #2 SetĆOutput Value during Profile

Percent Signal Output

3

SOC11

N43:367

*

Output #3 SetĆOutput Value during Profile

Percent Signal Output

3

SOC12

N43:368

*

Output #4 SetĆOutput Value during Profile

Percent Signal Output

3

SOC17

N43:373

0

Output #1 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

4

SOC18

N43:374

0

Output #2 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

4

SOC19

N43:375

0

Output #3 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

4

SOC20

N43:376

0

Output #4 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

4

SOC25

N43:381

0

Output #1 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

4

SOC26

N43:382

0

Output #2 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

4

SOC27

N43:383

0

Output #3 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

4

SOC28

N43:384

0

Output #4 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

4

SOC33

N43:389

*

Output #1 SetĆOutput Value at EndĆof Profile

Percent Signal Output

3

SOC34

N43:390

*

Output #2 SetĆOutput Value at EndĆof Profile

Percent Signal Output

3

SOC35

N43:391

*

Output #3 SetĆOutput Value at EndĆof Profile

Percent Signal Output

3

SOC36

N43:392

*

Output #4 SetĆOutput Value at EndĆof Profile

Percent Signal Output

3

SOC41

N43:397

0

Pressure Minimum Control Limit

Pressure

2

SOC42

N43:398

*

Pressure Maximum Control Limit

Pressure

2

SOC43

N43:399

*

Selected Pressure Valve, Output for Minimum

Percent Signal Output

3

SOC44

N43:400

*

Selected Pressure Valve, Output for Maximum

Percent Signal Output

3

SOC45

N43:401

0

Velocity Minimum Control Limit

Velocity along Axis

5

SOC46

N43:402

*

Velocity Maximum Control Limit

Velocity along Axis

5

SOC47

N43:403

*

Selected Velocity Valve, Output for Minimum

Percent Signal Output

3

SOC48

N43:404

*

Selected Velocity Valve, Output for Maximum

Percent Signal Output

3

SOC49

N43:405

100

Proportional Gain for Pressure Control

None

SOC50

N43:406

400

Integral Gain for Pressure Control

Inverse Time (Algorithm)

6

SOC51

N43:407

0

Derivative Gain for Pressure Control

Time (Algorithm)

7

SOC52

N43:408

200

Proportional Gain for Velocity Control

Inverse Time (Algorithm)

6

SOC53

N43:409

0

Feed Forward Gain for Velocity Control

None

SOC57

N43:413

0

Profile High Pressure Alarm Setpoint

Pressure

2

1

Time

2

Pressure

3

Percent Signal Output

4

Percent Signal Output per Second

00.00 to 99.99 Seconds 0000 to 9999 PSI 00.00 to 99.99 0000 to 9999

000.0 to 999.9 Bar

5

Velocity along Axis

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent

00.00 to 99.99 Inches per Second 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99

000.0 to 999.9 Millimeters per Second 00.00 to 99.99 Seconds (AĆB) 00.00 to 99.99 Seconds (AĆB)

* Refer to the appropriate section later in this chapter for information on this parameter