Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual
Page 107
Advertising
OSC Block Identifier
Selected
Pressure Valve
PID Pressure Algorithm
000 = Output 1
001 = Output 2
010 = Output 3
011 = Output 4
0 = Dependent Gains
1 = Independent Gains
Selected
Velocity Valve
000 = Output 1
001 = Output 2
010 = Output 3
011 = Output 4
Code:
Your value
Required initial value
loaded by ProĆSet 600
0 or 1
Load Initial Configuration Values
Chapter 7
7-26
Worksheet 7ĆL
Clamp Open Slow Configuration Block (OSC)
Control Word OSC01ĆBxx
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
ProĆSet 600 Addr. B37/bit
527 526 525 524 523 522 521 520 519 518 517 516 515 514 513 512
Value
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
0
Control Word OSC02ĆBxx
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
ProĆSet 600 Addr. B37/bit
543 542 541 540 539 538 537 536 535 534 533 532 531 530 529 528
Value
0
0
0
0
0
0
0
0
1
0
Advertising