Configure the qdc module's i/o chapter 3 – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual
Page 42
![background image](/manuals/579349/42/background.png)
Configure the QDC Module's I/O
Chapter 3
3-4
Table 3.A
Determine Initial SensorĆconfiguration Values for Worksheet 3ĆD
Category:
If your:
Then Use a Value Equal to:
Minimum Position
(Lines 1 and 9)
N/A
zero
Maximum Position
(Lines 2 and 10)
ram (screw) is fully extended to the
mold end (ram bottom), and the
mold closed position is zero.
maximum range value specified by the
manufacturer (full travel of the sensor
Analog Signal @ Min Position
sensor is forwardĆacting
low end of your selected range
(Lines 3 and 11)
sensor is reverseĆacting
high end of your selected range
Analog Signal @ Max Position
sensor is forwardĆacting
high end of your selected range
(Lines 4 and 12)
sensor is reverseĆacting
low end of your selected range
Minimum Pressure
(Lines 5 and 13)
N/A
minimum range value specified by the
manufacturer
Maximum Pressure
(Lines 6 and 14)
N/A
maximum range value specified by
manufacturer
Analog Signal @ Min Pressure
sensors are forwardĆacting
low end of your selected range
(Lines 7 and 15)
sensors are reverseĆacting
high end of your selected range
Analog Signal @ Max Pressure
sensors are forwardĆacting
high end of your selected range
(Lines 8 and 16)
sensors are reverseĆacting
low end of your selected range