9ć47, Span your clamp open velocity (flow) valve(s), Span your valves chapter 9 – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual

Page 204: Confirm critical values

Advertising
background image

Span Your Valves

Chapter 9

9-47

Span your clamp open velocity (flow) valve(s) for optimum velocity
performance. Do this in three parts:

Confirm critical values
Span your clamp open velocity (flow) valve(s)
Test valve linearity

Important: You may omit the next two parts of this section if you have
information on valve spanning. Many injection molding machine OEMs
and hydraulic valve manufacturers provide data on spanning the working
range of valves used on their machines. If this information is available
from your OEM for your machine’s clamp open velocity valve(s), enter the
values into velocity control limits FCC45-48, SCC45-48, TCC45-48, and
OSC45-48 and skip to Span Your Injection Pressure Valve.

Confirm Critical Values

Important: Confirm that your entries you configuration values (chapter 7)
and profile values (chapter 8) are as follows:

On Worksheet: Confirm Your Configuration:

With These Words or Bits:

ProĆset Addr:

7ĆI, 7ĆJ, 7ĆK, 7ĆL QDC module output to which you connected

your selected pressure control valve

FOC02ĆB06, B05, B04 = your selection

SOC02ĆB06, B05, B04 = your selection

TOC02ĆB06, B05, B04 = your selection

OSC02ĆB06, B05, B04 = your selection

B37/342, 341, 340

B37/406, 405, 404

B37/470, 469, 468

B37/534, 533, 532

Your unselected setĆoutput values

for outputs 1Ć4

FOC09Ć12 = your value

SOC09Ć12 = your value

TOC09Ć12 = your value

OSC09Ć12 = your value

N43:305Ć308

N43:365Ć368

N43:425Ć428

N43:485Ć488

All ramping is disabled with zero ramp rates

FOC17Ć20 = FOC25Ć28 = 0

SOC17Ć20 = SOC25Ć28 = 0

TOC17Ć20 = TOC25Ć28 = 0

OSC17Ć20 = OSC25Ć28 = 0

N43:313Ć316 N43:321Ć324

N43:373Ć376 N43:381Ć384

N43:433Ć436 N43:441Ć444

N43:493Ć496 N43:501Ć504

Velocity limits:

Minimum Control Limit

Maximum Control Limit

Selected Velocity Valve, Output for Min

Selected Velocity Valve, Output for Max

FOC45=SOC45=TOC45=OSC45=0

FOC46=SOC46=TOC46=OSC46=sys vel

FOC47=SOC47=TOC47=OSC47=your value

FOC48=SOC48=TOC48=OSC48=your value

N43:341, 401, 461, 521

N43:342, 402, 462, 522

N43:343, 403, 463, 523

N43:344, 404, 464, 524

8ĆE

Select inches/second for velocity units

OPC03ĆB14 = 1

B37/622

Zone overrun - start open slow on overrun

OPC03ĆB11 = 0

B37/619

Logical bridge - start next profile

OPC03ĆB10 = B09 = B08 = 0

B37/618, 617, 616

Expert Response Compensation (ERC) = Off

OPC04ĆB15 - B08 = 1

B37/639Ć632

OpenĆloop control

OPC04ĆB07 - B00 = 1

B37/631Ć624

FOC segment velocities

OPC09, 12, 15 = your values

N43:545, 548, 551

FOC endĆofĆsegment position setpoints

OPC11, 14, 17 = your values

N43:547, 550, 553

Start OSC position setpoint

OPC61 = your value

N43:597

Mold open position setpoint

OPC62 = your value

N43:598

If these are not your current values, we suggest that you correct them now
using the download procedure discussed in chapter 4.

Span Your Clamp Open

Velocity (Flow) Valve(s)