Span your low pressure close valve – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual

Page 160

Advertising
background image

Span Your Valves

Chapter 9

9-3

We recommend that you first span your low pressure close pressure valve
for optimum pressure performance. You do this in five parts:

Confirm critical values
Span your low pressure close pressure valve
Test value linearity with a low pressure close (LPC) profile
Set up tonnage (hydraulic clamps) or holding pressure (toggle clamps)
Set the profile pressure alarm

Important: You may omit the next four parts of this section if you have
the right information on valve spanning. Many injection molding machine
OEMs and hydraulic valve manufacturers provide data on spanning the
working range of valves used on their machines. If this information is
available from your OEM for your machine’s low pressure close valve,
enter the values into pressure control limits LPC41-44 and proceed to Set
the Profile Pressure Alarm.

Confirm Critical Values

Important: Confirm that your configuration values (chapter 7) and profile
values (chapter 8) for the low pressure close profile are as follows:

On Worksheet: Confirm Your Configuration:

With These Words or Bits:

ProĆSet Addr.

7ĆD

QDC module output to which you connected your

selected pressure control valve

LPC02ĆB06, B05, B04

your selection

B37/214, 213, 212

Your unselected setĆoutput values for outputs 1Ć4

LPC09ĆLPC12 = your values

N43:185Ć188

All ramping is disabled with zero ramp rates

LPC17ĆLPC20 = 0

LPC25ĆLPC28 = 0

N43:193Ć196

N43:201Ć204

Pressure limits:

Minimum Control Limit

Maximum Control Limit

Selected Pressure Valve, Output for Minimum

Selected Pressure Valve, Output for Maximum

LPC41 = 0

LPC42 = your value

LPC43 = your value

LPC44 = your value

N43:217

N43:218

N43:219

N43:220

8ĆA

Start LPC on zone overrun

CPC03ĆB11 = 0

B37/299

Expert Response Compensation (ERC) is

disabled

CPC04ĆB15 = 1

B37/319

OpenĆloop control

CPC04ĆB07 = 1

B37/311

Pressure setpoint

CPC37 = your value

N43:273

Start LPC position

CPC61 = your value

N43:297

Mold safe position

CPC62 = your value

N43:298

If these are not your current values, we suggest that you correct them now
using the download procedure discussed in chapter 4.

Span Your Low Pressure

Close Valve

Advertising