Tune Your Machine

Chapter 10

10-2

So far, you ran open-loop profiles with the QDC module’s PID and VelFF
control algorithms disabled. We suggest that you use open-loop control:

for spanning valves
for troubleshooting machine performance
when the machine has no pressure sensors for feedback

Important: You can achieve considerably better consistency of finished
parts when the QDC module operates in closed-loop control. With few
exceptions, you should run machine production with closed-loop profiles.

Correctly tuned closed-loop profiles are essential for precise, repeatable
operation. In chapter 7 you entered our recommended values. They may
give you desired machine performance.

Important: If you need to improve performance, continue with this
section. If not, skip to Injection Tuning Considerations for Producing Parts.

General Guidelines for Pressure Tuning

In this section we present two procedures:

Tune Pressure Loops without an Oscilloscope
Tune Pressure Loops with an Oscilloscope

Repeat either one of these procedures as needed for tuning the
pressure-control loop of these profiles:

Injection – Pressure vs. Position (or Time)
Pack and Hold – Pressure vs. Time
Plastication – Backpressure vs. Position (or Time)
Clamp Open (3) – Pressure vs. Position
Clamp Open Slow – Pressure vs. Position
Clamp Close (3) – Pressure vs. Position
Low Pressure Close – Pressure vs. Position

Follow these general guidelines when tuning closed-loop pressure profiles:

Disable

ramping

Disable Expert Response Compensation (ERC)

Reset ERC values to zero by setting DYC05-B15 (B34/463) = 1.

(The QDC module resets this bit to zero after resetting ERC values.)

Important: Gain constants differ between pressure profiles. The
dynamics of loads being moved and different hydraulic characteristics
warrant separate PID tuning considerations for each profile.

Important: In most cases, adding a derivative term to pressure control
algorithms makes it too sensitive and does not enhance loop stability.

ClosedĆloop Control

Tune ClosedĆloop

Pressure Control

Advertising