Configure the qdc module's i/o chapter 3 – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual

Page 53

Advertising
background image

Enter Your SWTL Configuration Values Here

Configure the QDC Module's I/O

Chapter 3

3-15

Configure the QDC module for SWTL as follows:

1.

Determine these SWTL values for ram (screw) and/or clamp travel
with respect to the range of physical travel.

SWTL deadband
Maximum SWTL
Minimum SWTL

2.

Record non-zero SWTL values on Worksheet 3-F. Zero values
disable the corresponding SWTLs.

ATTENTION: Leaving your SWTL settings at zero (MCC13,
14, 27, and 28) inhibits the QDC module from performing this
safety function.

Worksheet 3ĆF

SWTL Configuration Values

Control Word

ProĆSet 600 Addr. Value

Description

Units

MCC13

N40:9

Screw Minimum SWTL

Screw Axis Measured from zero

1

MCC14

N40:10

Screw Maximum SWTL

Screw Axis Measured from zero

1

MCC15

N40:11

10

Screw SWTL Deadband

As noted

1

MCC27

N40:23

Clamp Minimum SWTL

Clamp Axis Measured from zero

1

MCC28

N40:24

Clamp Maximum SWTL

Clamp Axis Measured from zero

1

MCC29

N40:25

10

Clamp SWTL Deadband

As noted

1

1

Incremental Distance

00.00 to 99.99 Inches

000.0 to 999.9 Millimeters

You may now download your adjusted values to the QDC module using
the MCC download procedure presented earlier in this chapter.