Configure the qdc module's i/o chapter 3 – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual
Page 53
Enter Your SWTL Configuration Values Here
Configure the QDC Module's I/O
Chapter 3
3-15
Configure the QDC module for SWTL as follows:
1.
Determine these SWTL values for ram (screw) and/or clamp travel
with respect to the range of physical travel.
SWTL deadband
Maximum SWTL
Minimum SWTL
2.
Record non-zero SWTL values on Worksheet 3-F. Zero values
disable the corresponding SWTLs.
ATTENTION: Leaving your SWTL settings at zero (MCC13,
14, 27, and 28) inhibits the QDC module from performing this
safety function.
Worksheet 3ĆF
SWTL Configuration Values
Control Word
ProĆSet 600 Addr. Value
Description
Units
MCC13
N40:9
Screw Minimum SWTL
Screw Axis Measured from zero
1
MCC14
N40:10
Screw Maximum SWTL
Screw Axis Measured from zero
1
MCC15
N40:11
10
Screw SWTL Deadband
As noted
1
MCC27
N40:23
Clamp Minimum SWTL
Clamp Axis Measured from zero
1
MCC28
N40:24
Clamp Maximum SWTL
Clamp Axis Measured from zero
1
MCC29
N40:25
10
Clamp SWTL Deadband
As noted
1
1
Incremental Distance
00.00 to 99.99 Inches
000.0 to 999.9 Millimeters
You may now download your adjusted values to the QDC module using
the MCC download procedure presented earlier in this chapter.