Span Your Valves

Chapter 9

9-9

Span your clamp close pressure valve(s) for optimum performance. Do
this in four parts:

Confirm critical values
Span your clamp close pressure valve(s)
Test valve linearity
Set pressure alarm setpoints

Important: You may omit the next three parts of this section if you have
the right information on valve spanning. Many injection molding machine
OEMs and hydraulic valve manufacturers provide data on spanning the
working range of valves used on their machines. If this information is
available from your OEM for your machine’s clamp close pressure
valve(s), enter the values into pressure control limits FCC41-44,
SCC41-44, and TCC41-44 and proceed to Set Profile Pressure Alarms.

Confirm Critical Values

Important: Confirm that your entries for configuration values (chapter 7)
and profile values (chapter 8) for clamp close profiles are as follows:

On Worksheet: Confirm Your Configuration:

With These Words or Bits:

ProĆSet Addr.:

7ĆA, 7ĆB, 7ĆC

QDC module output to which you connect

your selected pressure control valve

FCC02ĆB06,B05,B04 = your selection

SCC02ĆB06,B05,B04 = your selection

TCC02ĆB06,B05,B04 = your selection

B37/22, 21, 20

B37/86, 85, 84

B37/150,149,148

Your unselected setĆoutput values for outputs

1Ć4

FCC09Ć12 = your values

SCC09Ć12 = your values

TCC09Ć12 = your values

N43:5Ć8

N43:65Ć68

N43:125Ć128

All ramping is disabled with zero ramp rates

FCC17Ć20 = FCC25Ć28 = 0,

SCC17Ć20 = SCC25Ć28 = 0

TCC17Ć20 = TCC25Ć28 = 0

N43:13Ć16 N43:21Ć24

N43:73Ć76 N43:81Ć84

N43:133Ć136 N43:141Ć144

Pressure limits:

Minimum Control Limit

Maximum Control Limit

Selected Pressure Valve, Output for Min

Selected Pressure Valve, Output for Max

FCC41=SCC41=TCC41=0

FCC42=SCC42=TCC42=your value

FCC43=SCC43=TCC43=your value

FCC44=SCC44=TCC44=your value

N43:37, 97, 157

N43:38, 98, 158

N43:39, 99, 159

N43:40, 100, 160

8ĆA

Pressure vs. Position Control

CPC03ĆB04 = B02 = B00 = 1

B37/292, 290, 288

Logical bridge

CPC03ĆB10, B09, B08 = 0

B37/298, 297, 296

Mold Protection

CPC03ĆB11 = 0

B37/299

OpenĆloop control

CPC04ĆB07 = B05ĆB00 = 1

B37/311, 309Ć304

Expert Response Compensation (ERC) = Off CPC04ĆB15 = B13ĆB08 = 1

B37/319, 317Ć312

FCC pressure setpoints

CPC10, 13, 16 = your value

N43:246, 249, 252

FCC endĆofĆsegment position setpoints

CPC11, 14, 17 = your value

N43:247,250,253

Start LPC position

CPC61 = your value

N43:297

Mold Safe Position

CPC62 = your value

N43:298

If these are not your current values, we suggest that you correct them now
using the download procedure discussed in chapter 4.

Span Your Clamp Close

Pressure Valve(s)