Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual
Page 60
Overview of Remaining
Configuration Procedures
Chapter 4
4-5
Learn the following procedure because you will use it often.
1.
For the block you want to download (subject block), get its ID
number from Table 4.A and enter it into DYC61.
Table 4.A
Information Required to Download a Command Block
Block to
Download:
ProĆSet 600
Block ID.:
ProĆSet 600
Download Command Bit:
Companion
Block:
JGC
02
B21/1
FCC
03
B21/2
CPC
SCC
04
B21/3
CPC
TCC
05
B21/4
CPC
LPC
06
B21/5
CPC
CPC
07
B21/6
INC
08
B21/7
IPC
IPC
09
B21/8
PKC
10
B21/9
HPC
HDC
11
B21/10
HPC
HPC
12
B21/11
PRC
13
B21/12
PLC
14
B21/13
PPC
PPC
15
B21/14
PSC
16
B21/15
FOC
17
B21/16
OPC
SOC
18
B21/17
OPC
TOC
19
B21/18
OPC
OSC
20
B21/19
OPC
OPC
21
B21/20
2.
Confirm that the QDC module returns the ID in SYS61.
Important: If the value returned in SYS61 is NOT the ID number
you entered, you have an error in the MCC or DYC block:
If SYS61 has
this value:
This block
has errors:
Fix them as follows:
1
MCC
Refer to chapter 3 Correct Any DataĆentry Errors in MCC"
25
DYC
Go to steps 8 and 9 of this procedure.
Fix MCC and DYC errors before starting the download procedure
MCC and DYC errors are corrected when SYS61
≠
1 or 25, but
when SYS61=DYC61=ID number of the subject block