Load initial configuration values chapter 7 – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual

Page 94

Advertising
background image

Enter Your Values Here

Load Initial Configuration Values

Chapter 7

7-13

Worksheet 7ĆE(continued)
Injection Configuration Block (INC)

Control Word ProĆSet 600 Addr. Value

Description

Units

INC05

N44:1

1000

Minimum ERC PercentageĆĆVelocity

Percent

8

INC06

N44:2

1000

Minimum ERC PercentageĆĆPressure

Percent

8

INC09

N44:5

*

Output #1 SetĆoutput Value During Profile

Percent Signal Output

4

INC10

N44:6

*

Output #2 SetĆoutput Value During Profile

Percent Signal Output

4

INC11

N44:7

*

Output #3 SetĆoutput Value During Profile

Percent Signal Output

4

INC12

N44:8

*

Output #4 SetĆoutput Value During Profile

Percent Signal Output

4

INC17

N44:13

0

Output #1 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC18

N44:14

0

Output #2 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC19

N44:15

0

Output #3 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC20

N44:16

0

Output #4 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC25

N44:21

0

Output #1 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC26

N44:22

0

Output #2 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC27

N44:23

0

Output #3 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC28

N44:24

0

Output #4 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC41

N44:37

0

Pressure Minimum Control Limit

Pressure

3

INC42

N44:38

*

Pressure Maximum Control Limit

Pressure

3

INC43

N44:39

*

Selected Pressure Valve, Output for Minimum

Percent Signal Output

4

INC44

N44:40

*

Selected Pressure Valve, Output for Maximum

Percent Signal Output

4

INC45

N44:41

0

Velocity Minimum Control Limit

Velocity along Axis

2

INC46

N44:42

*

Velocity Maximum Control Limit

Velocity along Axis

2

INC47

N44:43

*

Selected Velocity Valve, Output for Minimum

Percent Signal Output

4

INC48

N44:44

*

Selected Velocity Valve, Output for Maximum

Percent Signal Output

4

INC49

N44:45

100

Proportional Gain for Pressure Control

None

INC50

N44:46

400

Integral Gain for Pressure Control

Inverse Time (Algorithm)

6

INC51

N44:47

0

Derivative Gain for Pressure Control

Time (Algorithm)

7

INC52

N44:48

200

Proportional Gain for Velocity Control

Inverse Time (Algorithm)

6

INC53

N44:49

0

Feed Forward Gain for Velocity Control

None

INC57

N44:53

0

Profile High Pressure Alarm Setpoint

Pressure

3

2

Velocity along Axis

3

Pressure

4

Percent Signal Output

00.00 to 99.99 inches per second 0000 to 9999 PSI 00.00 to 99.99

000.0 to 999.9 millimeters per second 000.0 to 999.9 Bar

5

Percent Signal Output per Second

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent

0000 to 9999 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99

00.00 to 99.99 Seconds (AĆB) 00.00 to 99.99 Seconds (AĆB)

* Refer to the appropriate section later in this chapter for information on this parameter