Load Initial Profile Values

Chapter 8

8-8

4.

Enter your FCC end-of-segment position setpoints for CPC11, 14,
and 17 on Worksheet 8-A.

We entered zero for the remaining position setpoints on Worksheet 8-A.

The valve spanning procedures in chapter 9 require these initial values.
We help you select correct final values for your application in chapter 10.
For additional information, refer to Section 3 of the Plastic Molding
Module Reference Manual (publication 1771-6.5.88).

TonnageĆcomplete Pressure Setpoint

(CPC63)
The QDC module compares clamp pressure with this value, and sets
master status bit SYS03-B02 when clamp pressure equals or exceeds this
entry, and clamp position is equal to or less than CPC62.

We entered zero for the tonnage watchdog timer preset.

The valve spanning procedures in chapter 9 require this initial value. We
help you select correct final values for your application in chapter 10. For
additional information, refer to Section 3 of the Plastic Molding Module
Reference Manual (publication 1771-6.5.88).

After you determine initial values and entering them on Worksheet 8-A,
you are ready to proceed.

1.

Enter all worksheet values into your PLC-5 data table.

Important: Be sure that you have not altered any setpoints, and that you
have entered each and every setpoint exactly as on the worksheet.

2.

Use the procedure described in chapter 4 to download command
blocks to the QDC module. We repeat the CPC block download data.

Block to

Download:

ProĆSet 600

Block ID:

Download

Command Bit:

Companion

Block:

CPC

07

B21/6

none

3.

Check SYS61 and SYS62 for programming errors. Correct as needed.