Jog Your Machine
Chapter 5
5-2
Worksheet 5-A lists all words in which you must enter values to
successfully configure your QDC module for jogging the ram (screw) and
clamp forward and backward. Use it to record:
initial
values
Enter initial values just sufficient to jog in the desired direction.
Keep this information in mind:
The numbers you enter are %-signal output.
For a range of –10 to +10 Vdc, zero output occurs @ 50%
(See Warning on next page.)
Later in this chapter you modify these values to obtain desired results.
pressure alarm setpoints for ram (screw) and clamp jogs
The QDC module sets an alarm any time ram (screw) and/or clamp
pressure equals or exceeds the corresponding alarm setpoints during a
jog. A zero entry inhibits alarm actuation.
Important:
High pressure alarms that you set in chapter 3 are also active
during jog functions.
Jog-specific high pressure alarms for eject jogs are NOT activated
in a QDC module configured for inject and clamp mode.
Determine Initial Jog Values