Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual

Page 63

Advertising
background image

Jog Your Machine

Chapter 5

5-2

Worksheet 5-A lists all words in which you must enter values to
successfully configure your QDC module for jogging the ram (screw) and
clamp forward and backward. Use it to record:

initial

values

Enter initial values just sufficient to jog in the desired direction.
Keep this information in mind:

The numbers you enter are %-signal output.
For a range of –10 to +10 Vdc, zero output occurs @ 50%

(See Warning on next page.)

Later in this chapter you modify these values to obtain desired results.

pressure alarm setpoints for ram (screw) and clamp jogs

The QDC module sets an alarm any time ram (screw) and/or clamp
pressure equals or exceeds the corresponding alarm setpoints during a
jog. A zero entry inhibits alarm actuation.

Important:

High pressure alarms that you set in chapter 3 are also active

during jog functions.

Jog-specific high pressure alarms for eject jogs are NOT activated

in a QDC module configured for inject and clamp mode.

Determine Initial Jog Values