Load initial profile values chapter 8 – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual

Page 140

Advertising
background image

Enter Your Values Here

Load Initial Profile Values

Chapter 8

8-19

Worksheet 8ĆC (continued)
Pack/Hold Profile Block (HPC)

Control Word

ProĆSet 600 Addr. Value

Description

Units

HPC10

N44:246

*

Pack Segment 1 Ram Pressure Setpoint

Pressure

3

HPC11

N44:247

100

Pack Segment 1 Time Setpoint

Time

1

HPC13

N44:249

*

Pack Segment 2 Pressure Setpoint

Pressure

3

HPC14

N44:250

100

Pack Segment 2 Time Setpoint

Time

1

HPC16

N44:252

*

Pack Segment 3 Pressure Setpoint

Pressure

3

HPC17

N44:253

100

Pack Segment 3 Time Setpoint

Time

1

HPC19

N44:255

*

Pack Segment 4 Pressure Setpoint

Pressure

3

HPC20

N44:256

100

Pack Segment 4 Time Setpoint

Time

1

HPC22

N44:258

*

Pack Segment 5 Pressure Setpoint

Pressure

3

HPC23

N44:259

100

Pack Segment 5 Time Setpoint

Time

1

HPC25

N44:261

0

Pack Profile Ram Pressure Offset

Pressure

3

HPC27

N44:263

*

Hold Segment 1 Ram Pressure Setpoint

Pressure

3

HPC28

N44:264

100

Hold Segment 1 Time Setpoint

Time

1

HPC30

N44:266

*

Hold Segment 2 Ram Pressure Setpoint

Pressure

3

HPC31

N44:267

100

Hold Segment 2 Time Setpoint

Time

1

HPC33

N44:269

*

Hold Segment 3 Pressure Setpoint

Pressure

3

HPC34

N44:270

100

Hold Segment 3 Time Setpoint

Time

1

HPC36

N44:272

*

Hold Segment 4 Ram Pressure Setpoint

Pressure

3

HPC37

N44:273

100

Hold Segment 4 Time Setpoint

Time

1

HPC39

N44:275

*

Hold Segment 5 Ram Pressure Setpoint

Pressure

3

HPC40

N44:276

100

Hold Segment 5 Time Setpoint

Time

1

HPC42

N44:278

0

Hold Profile Pressure Offset

Pressure

3

HPC61

N44:297

0

Cure Timer Preset

Time

4

1

Time

3

Pressure

4

Time

00.00 to 99.99 seconds

0000 to 9999 PSI

000.0 to 999.9 seconds

000.0 to 999.9 Bar

* Refer to the appropriate section later in this chapter for information on this parameter