Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual

Page 74

Advertising
background image

Select Command and Status Bits

to Sequence Machine Operation

Chapter 6

6-3

Table 6.C

Status and Command Bit Interaction for Automatic Functions

For this

Profile/Movement:

During Execution

this bit in B34 is:

At Completion

this bit in B34 is:

At completion

If this

Then this

command bit is:

status bit is:

SET

RESET

SET

RESET

also SET

also SET

1st Clamp Close

SYS21ĆB00 SYS02ĆB00 SYS02ĆB00 SYS21ĆB00 CPC03ĆB08

SYS22ĆB00

2nd Clamp Close

SYS21ĆB01 SYS02ĆB01 SYS02ĆB01 SYS21ĆB01 CPC03ĆB09

SYS22ĆB01

3rd Clamp Close

SYS21ĆB02 SYS02ĆB02 SYS02ĆB02 SYS21ĆB02 CPC03ĆB10

SYS22ĆB02

Low Pressure Close SYS21ĆB03 SYS02ĆB03 SYS02ĆB03 SYS21ĆB03 ---

SYS22ĆB03

Injection

SYS21ĆB04 SYS02ĆB04 SYS02ĆB04 SYS21ĆB04 ---

---

Pack

SYS21ĆB05 SYS02ĆB05 SYS02ĆB05 SYS21ĆB05 ---

---

Hold

SYS21ĆB06 SYS02ĆB06 SYS02ĆB06 SYS21ĆB06 HPC03ĆB08

SYS22ĆB06

PreĆdecompression

SYS21ĆB07 SYS02ĆB07 SYS02ĆB07 SYS21ĆB07 HPC03ĆB09

SYS22ĆB07

Plastication

SYS21ĆB08 SYS02ĆB08 SYS02ĆB08 SYS21ĆB08 PPC03ĆB08

SYS22ĆB08

PostĆdecompression SYS21ĆB09 SYS02ĆB09 SYS02ĆB09 SYS21ĆB09 ---

SYS22ĆB09

1st Clamp Open

SYS21ĆB10 SYS02ĆB10 SYS02ĆB10 SYS21ĆB10 OPC03ĆB08

SYS22ĆB10

2nd Clamp Open

SYS21ĆB11 SYS02ĆB11 SYS02ĆB11 SYS21ĆB11 OPC03ĆB09

SYS22ĆB11

3rd Clamp Open

SYS21ĆB12 SYS02ĆB12 SYS02ĆB12 SYS21ĆB12 OPC03ĆB10

SYS22ĆB12

Clamp Open Slow

SYS21ĆB13 SYS02ĆB13 SYS02ĆB13 SYS21ĆB13 ---

SYS22ĆB13

Advertising