Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual

Page 182

Advertising
background image

Span Your Valves

Chapter 9

9-25

Set New Values for the Velocity vs. Position Profile

If necessary, refer to chapter 8 for when you determine the following:

8ĆB

Velocity vs. position algorithm

IPC03ĆB01 = B00 = 0

B38/96, 97

Transition setpoints:

Time limit

Ram (screw) position

Ram (screw) pressure

Minimum position for pressure transition

IPC60 = above typical

IPC61 = estimated top of cushion

IPC62 = below mold flash pressure

IPC64 = zero to inhibit

N44:116

N44:117

N44:118

N44:120

Download new values to the QDC module by downloading INC and IPC.

Important: If downloading from your programming terminal, download
INC followed by IPC (chapter 4).

To download:

Set: B21/

INC

7

IPC

8

Span Your Injection Velocity Valve

Span your injection valve for smooth operation at the highest desired
velocity. Do this by finding optimum values for these words:

Minimum Velocity Control Limit INC45 (N44:41)
Maximum Velocity Control Limit INC46 (N44:42)
Selected Velocity Valve, Output for Minimum INC47 (N44:43)
Selected Velocity Valve, output for maximum INC48 (N44:44)

Important: If PanelView is operational for injection profiles, use it to:

observe

actuals

change and download setpoints
run

profiles

Important:

We suggest that you read this procedure before starting.

ATTENTION: As with any machine start-up, install a test
mold. Programming errors, configuration errors, or hydraulic
problems could lead to machine damage or injury to personnel.

ATTENTION: Be sure all machine guards and shields are in
place before proceeding.

Advertising