9ć14, Span your clamp close velocity (flow) valve(s), Span your valves chapter 9 – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual

Page 171: Confirm critical values

Advertising
background image

Span Your Valves

Chapter 9

9-14

Span your clamp close velocity (flow) valve(s) for optimum velocity
performance. Do this in three parts:

Confirm critical values
Span your clamp close velocity (flow) valve(s)
Test valve linearity with a velocity vs. position profile

Important: You may omit this section if you have the right information on
valve spanning. Many injection molding machine OEMs and hydraulic
valve manufacturers provide data on spanning the working range of valves
used on their machines. If this information is available from your OEM
for your machine’s clamp close velocity valve(s), enter the values into
velocity control limits FCC45-48, SCC45-48, and TCC45-45 and proceed
to Span your Open Slow Valves.

Confirm Critical Values

Important: Confirm that your entries for configuration values (chapter 7)
and profile values (chapter 8) for clamp close profiles are as follows:

On Worksheet: Confirm Your Configuration:

With These Words or Bits:

ProĆSet Addr.

7ĆA, 7ĆB, 7ĆC

QDC module output to which you connected

your selected velocity control valve

FCC02ĆB02,B01,B00 = your selection

SCC02ĆB02,B01,B00 = your

selection

TCC02ĆB02,B01,B00 = your selection

B37/22, 21, 20

B37/86, 85, 84

B37/150,149,148

Your unselected setĆoutput values for outputs

1Ć4

FCC09Ć12 = your value

SCC09Ć12 = your value

TCC09Ć12 = your value

N43:5Ć8

N43:65Ć68

N43:125Ć128

All ramping is disabled with zero ramp rates

FCC17Ć20 = FCC25Ć28 = 0

SCC17Ć20 = SCC25Ć28 = 0

TCC17Ć20 = TCC25Ć28 = 0

N43:13Ć16 N43:21Ć24

N43:73Ć76 N43:81Ć84

N43:133Ć136

N43:141Ć144

Velocity limits:

Minimum Control Limit

Maximum Control Limit

Selected Velocity Valve, Output for Min

Selected Velocity Valve, Output for Max

FCC45=SCC45=TCC45=0

FCC46=SCC46=TCC46=sys vel

FCC47=SCC47=TCC47=your value

FCC48=SCC48=TCC48=your value

N43:41, 101, 161

N43:42, 102, 162

N43:43, 103, 163

N43:44, 104, 164

8ĆA

Selected inches/second as velocity units

CPC03ĆB14 = 1

B37/302

Mold protection

CPC03ĆB11 = 0

B37/299

Logical bridge

CPC03ĆB10 = B09 = B08 = 0

B37/298, 297, 296

Expert Response Compensation (ERC) = Off

CPC04ĆB15 = B13ĆB08 = 1

B37/319, 317Ć312

OpenĆloop control

CPC04ĆB07 = B05ĆB00 = 1

B37/311, 309Ć304

EndĆof Segment position setpoints

CPC11,14,17

N43:247, 250, 253

Start LPC position

CPC61

N43:297

Mold Safe Position

CPC62

N43:298

If these are not your current values, we suggest that you correct them now
using the download procedure discussed in chapter 4.

Span Your Clamp Close

Velocity (Flow) Valve(s)