Blank worksheets appendix a – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual

Page 260

Advertising
background image

Enter Your Values Here

Blank Worksheets

Appendix A

A-15

Worksheet 7ĆE (continued)
Injection Configuration Block (INC)

Control Word ProĆSet 600 Addr. Value

Description

Units

INC05

N44:1

Minimum ERC PercentageĆĆVelocity

Percent

8

INC06

N44:2

Minimum ERC PercentageĆĆPressure

Percent

8

INC09

N44:5

Output #1 SetĆoutput Value During Profile

Percent Signal Output

4

INC10

N44:6

Output #2 SetĆoutput Value During Profile

Percent Signal Output

4

INC11

N44:7

Output #3 SetĆoutput Value During Profile

Percent Signal Output

4

INC12

N44:8

Output #4 SetĆoutput Value During Profile

Percent Signal Output

4

INC17

N44:13

Output #1 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC18

N44:14

Output #2 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC19

N44:15

Output #3 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC20

N44:16

Output #4 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC25

N44:21

Output #1 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC26

N44:22

Output #2 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC27

N44:23

Output #3 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC28

N44:24

Output #4 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC41

N44:37

Pressure Minimum Control Limit

Pressure

3

INC42

N44:38

Pressure Maximum Control Limit

Pressure

3

INC43

N44:39

Selected Pressure Valve, Output for Minimum

Percent Signal Output

4

INC44

N44:40

Selected Pressure Valve, Output for Maximum

Percent Signal Output

4

INC45

N44:41

Velocity Minimum Control Limit

Velocity along Axis

2

INC46

N44:42

Velocity Maximum Control Limit

Velocity along Axis

2

INC47

N44:43

Selected Velocity Valve, Output for Minimum

Percent Signal Output

4

INC48

N44:44

Selected Velocity Valve, Output for Maximum

Percent Signal Output

4

INC49

N44:45

Proportional Gain for Pressure Control

None

INC50

N44:46

Integral Gain for Pressure Control

Inverse Time (Algorithm)

6

INC51

N44:47

Derivative Gain for Pressure Control

Time (Algorithm)

7

INC52

N44:48

Proportional Gain for Velocity Control

Inverse Time (Algorithm)

6

INC53

N44:49

Feed Forward Gain for Velocity Control

None

INC57

N44:53

Profile High Pressure Alarm Setpoint

Pressure

3

2

Velocity along Axis

3

Pressure

4

Percent Signal Output

00.00 to 99.99 inches per second

0000 to 9999 PSI

00.00 to 99.99

000.0 to 999.9 millimeters per second

000.0 to 999.9 Bar

5

Percent Signal Output per Second

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent

0000 to 9999

00.00 to 99.99 Minutes (ISA)

00.00 to 99.99 Minutes (ISA)

00.00 to 99.99

00.00 to 99.99 Seconds (AĆB)

00.00 to 99.99 Seconds (AĆB)

* Refer to the appropriate section later in this chapter for information on this parameter

Advertising