Select Command and Status Bits

to Sequence Machine Operation

Chapter 6

6-10

Table

6.G

(continued)

Command and Configuration Bits

Operation:

Function Enabled

(when = 1):

ProĆSet

Address:

QDC Block

Addr.:

Logical Bridge

set output @ end of 1st clamp close profile

(0 = start 2nd clamp close profile)

B37/296

CPC03ĆB08

set output @ end of 2nd clamp close profile

(0 = start 3rd clamp close profile)

B37/297

CPC03ĆB09

set output @ end of 3rd clamp close profile

(0 = start clamp LP close profile)

B37/298

CPC03ĆB10

set output @ end of hold profile

(0 = start preĆdecompress movement @ end of hold)

B38/296

HPC03ĆB08

set output @ end of preĆdecompress movement

(0 = start plastication profile @ end of preĆdecompress)

B38/297

HPC03ĆB09

set output at end of plastication profile

(0 = start postĆdecompression at end of plastication)

B38/488

PPC03ĆB08

set output @ end of 1st clamp open profile

(0 = start 2nd clamp open profile)

B37/616

OPC03ĆB08

set output @ end of 2nd clamp open profile

(0 = start 3rd clamp open profile)

B37/617

OPC03ĆB09

set output @ end of 3rd clamp open profile

(0 = start clamp open slow profile)

B37/618

OPC03ĆB10

Configured

Protection from

ClampĆzone

Overrun

If a clamp close profile overruns the

mold protection zone:

0 = start LPĆclose profile

1 = stop and zero outputs

B37/299

CPC03ĆB11

If a clamp open profile overruns the

clamp open slow zone

0 = start open slow profile

1 = stop and zero outputs

B37/619

OPC03ĆB11