Configure the QDC Module's I/O

Chapter 3

3-14

You also have the option of configuring the following QDC features:

Use this Option:

For this Benefit:

Software Travel Limits

to guard against damaging the nozzle assembly or seals

Pressure Alarm Time Delay

to warn of excessive pressure without nuisance alarms

Digital Filter

to compensate for noise on position inputs

Configure Software Travel Limits

You may want to use the software restrictions, Figure 3.1, to stop the travel
of your ram (screw) or clamp before either reaches its maximum limits
(configured earlier in this chapter).

Figure 3.1

Software Restrictions

Physical Travel Range

Max Position Min Position

d

d

Max SWTL Min SWTL

d = deadband

Safe Zone

Important: The orientation shown (movement left to right) is for clamp
SWTLs. By convention, ram (screw) orientation is reversed.

During normal machine operation and whenever your cylinder travels
outside the safe zone (outside the specified software travel limits, SWTL),
the QDC module:

sets an alarm status bit
forces its outputs to zero
ignores all profile commands (except set-output and jogs) until you jog

the cylinder back through the deadband into the safe zone at either end

The deadband guards against sensor noise flickering the SWTL alarms and
requires that the operator jog the cylinder a set distance away from the
software overtravel limit. We recommend a value of 00.10 inch as a
starting deadband. Your sensor may require a greater deadband.

ATTENTION: The QDC module ignores SWTL alarms when
jogging or when performing a set-output operation.