Enter Your Values Here

Load Initial Configuration Values

Chapter 7

7-15

Worksheet 7ĆF (continued)
Pack Configuration Block (PKC)

Control Word ProĆSet 600 Addr. Value

Description

Units

PKC06

N44:122

1000

Minimum ERC PercentageĆĆPressure

Percent

8

PKC09

N44:125

*

Output #1 SetĆoutput Value During Profile

Percent Signal Output

4

PKC10

N44:126

*

Output #2 SetĆoutput Value During Profile

Percent Signal Output

4

PKC11

N44:127

*

Output #3 SetĆoutput Value During Profile

Percent Signal Output

4

PKC12

N44:128

*

Output #4 SetĆoutput Value During Profile

Percent Signal Output

4

PKC17

N44:133

0

Output #1 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

PKC18

N44:134

0

Output #2 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

PKC19

N44:135

0

Output #3 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

PKC20

N44:136

0

Output #4 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

PKC25

N44:141

0

Output #1 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

PKC26

N44:142

0

Output #2 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

PKC27

N44:143

0

Output #3 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

PKC28

N44:144

0

Output #4 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

PKC41

N44:157

0

Pressure Minimum Control Limit

Pressure

3

PKC42

N44:158

*

Pressure Maximum Control Limit

Pressure

3

PKC43

N44:159

*

Selected Pressure Valve, Output for Minimum

Percent Signal Output

4

PKC44

N44:160

*

Selected Pressure Valve, Output for Maximum

Percent Signal Output

4

PKC49

N44:165

100

Proportional Gain for Pressure Control

None

PKC50

N44:166

400

Integral Gain for Pressure Control

Inverse Time (Algorithm)

6

PKC51

N44:167

0

Derivative Gain for Pressure Control

Time (Algorithm)

7

PKC57

N44:173

0

Profile High Pressure Alarm Setpoint

Pressure

3

3

Pressure

4

Percent Signal Output

0000 to 9999 PSI 00.00 to 99.99

000.0 to 999.9 Bar

5

Percent Signal Output per Second

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent

0000 to 9999 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99

00.00 to 99.99 Seconds (AĆB) 00.00 to 99.99 Seconds (AĆB)