Span Your Valves

Chapter 9

9-29

What You Have Accomplished

The valve-spanning procedure you just completed has defined the:

range of ram (screw) velocity during any injection profile

end-of-range maximum and minimum signal levels for linear control of

the injection velocity valve in open-loop control

For this

range limit

When trying to obtain

the velocity in:

The QDC module drives the selected

velocity valve to % output signal in:

Minimum

INC45

INC47

Maximum

INC46

INC48

Now for all open-loop injection velocity profiles, the QDC module
assumes a liner relationship between ram velocity and signal output.

Note that there are no velocity profile alarms.