We recommend that you span your plastication pressure valve for optimum
plastication performance in four parts:

Confirm critical values
Span your plastication pressure valve
Test valve linearity with a plastication backpressure vs. position profile
Set the profile pressure alarm

Important: You may omit the next three parts of this section if you have
the right information on valve spanning. Many injection molding machine
OEMs and hydraulic valve manufacturers provide data on spanning the
working range of valves used on their machines. If this information is
available from your OEM for your machine’s plastication pressure valve,
enter the values into pressure control limits PLC41-44 and proceed to Set
the Profile Pressure Alarm.

Confirm Critical Values

Important: Confirm that all entries you made for configuration values
(chapter 7) and profile values (chapter 8) are as follows:

On Worksheet Confirm Your Configuration

With These Words or Bits

ProĆSet Addr

7ĆH

QDC module output to which you connected

your plastication pressure control valve

PLC02ĆB06, B05, B04

B38/404Ć406

SetĆoutput values for unselected valves

PLC09Ć12 = your values

N44:365Ć368

All ramping is disabled with zero ramp rates

PLC17Ć20 = 0

PLC25Ć28 = 0

N44:373Ć376

N44:381Ć384

EndĆofĆprofile SetĆoutput values

PLC33Ć36 for zero output

N44:389Ć392

Pressure limits:

Minimum Pressure Control Limit

Maximum Pressure Control Limit

Selected Pressure Valve, Output for Min

Selected Pressure Valve, Output for Max

PLC41 = 0

PLC42 = max attainable backpressure

PLC43 = your value

PLC44 = your value

N44:397

N44:398

N44:399

N44:400

8ĆD

Backpressure vs Position algorithm

PPC03ĆB00 = 0

B38/480

Logical bridge to stop and set outputs before

postĆdecompression

PPC03ĆB08 = 1

B38/488

OpenĆloop control

PPC04ĆB01 = B00 = 1

B38/496, 497

Expert Response Compensation (ERC) = Off

PPC04ĆB09 = B08 = 1

B38/504, 505

Backpressure setpoints

PPC10,14, 18, 22, 26, 30, 34, 38, 42,

46, 50 all equal to max desired

backpressure

start @ N44:426

end @ N44:466

Position setpoints

PPC11,15,19,23,27,31,35,39,43,47

equal segments over shot size

start @ N44:427

end @ N44:463

Shot size

PPC62 = typical for your machine

N44:478

If these are not your current values, we suggest that you correct them now
and download them using the download procedure discussed in chapter 4.

Span Your Plastication