Blank worksheets appendix a – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual

Page 247

Advertising
background image

Select Output 1 Range with bits 01, 00

Select Output 2 Range with bits 03, 02

Select Output 3 Range with bits 05, 04

Select Output 4 Range with bits 07, 06

Output Range

-10 to +10V dc

0

0

0 to +10V dc

0

1

4 to 20 mA

1

0

Not connected

1

1

Enter Your Initial Values Here

Blank Worksheets

Appendix A

A-2

Worksheet 3ĆC
Selecting Output Ranges for your Valves

Control Word MCC04ĆBxx

15

14 13 12 11

10

09 08 07 06 05 04 03 02 01 00

ProĆSet 600 Addr. B34/bit

575 574 573 572 571 570 569 568 567 566 565 564 563 562 561 560

Value

1

1

1

1

1

1

1

1

Example: If you select 0-10V dc for all four output ranges: MCC04 = 11111111 01010101.

Important: Software output selections must match jumper settings for each respective output.

Worksheet 3ĆD
Determining Initial SensorĆconfiguration Values

Input

Line

Control Word

ProĆSet 600 Addr. Value

Description

Units

1

1

MCC09

N40:5

Minimum Screw Position

Screw Axis Measured from zero

1

2

MCC10

N40:6

Maximum Screw Position

Screw Axis Measured from zero

1

3

MCC11

N40:7

Analog Signal @ Min Screw Position

Input Signal Range

2

4

MCC12

N40:8

Analog Signal @ Max Screw Position

Input Signal Range

2

2

5

MCC17

N40:13

Minimum Screw Pressure

Screw Pressure

3

6

MCC18

N40:14

Maximum Screw Pressure

Screw Pressure

3

7

MCC19

N40:15

Analog Signal @ Min Screw Pressure

Input Signal Range

2

8

MCC20

N40:16

Analog Signal @ Max Screw Pressure

Input Signal Range

2

3

9

MCC23

N40:19

Minimum Clamp Position

Clamp Axis Measured from zero

1

10

MCC24

N40:20

Maximum Clamp Position

Clamp Axis Measured from zero

1

11

MCC25

N40:21

Analog Signal @ Min Clamp Position

Input Signal Range

2

12

MCC26

N40.22

Analog Signal @ Max Clamp Position

Input Signal Range

2

4

13

MCC31

N40:27

Minimum Clamp Pressure

Clamp Pressure

3

14

MCC32

N40:28

Maximum Clamp Pressure

Clamp Pressure

3

15

MCC33

N40:29

Analog Signal @ Min Clamp Pressure

Input Signal Range

2

16

MCC34

N40:30

Analog Signal @ Max Clamp Pressure Input Signal Range

2

1

Incremental Distance

2

Input Signal Range

3

Pressure

00.00 to 99.99in

00.00 to 10.00VDC or

0000 to 9999 PSI

000.0 to 999.9mm

01.00 to 05.00VDC or

000.0 to 999.9 Bar

04.00 to 20.00MADC

Advertising