Load initial configuration values chapter 7 – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual

Page 106

Advertising
background image

Enter Your Values Here

Load Initial Configuration Values

Chapter 7

7-25

Worksheet 7ĆK (continued)
Third Clamp Open Configuration Block (TOC)

Control Word ProĆSet 600 Addr. Value

Description

Units

TOC05

N43:421

1000

Minimum ERC PercentageĆĆVelocity

Percent

8

TOC06

N43:422

1000

Minimum ERC PercentageĆĆPressure

Percent

8

TOC08

N43:424

0

Profile Watchdog Timer Preset

Time

1

TOC09

N43:425

*

Output #1 SetĆOutput Value during Profile

Percent Signal Output

3

TOC10

N43:426

*

Output #2 SetĆOutput Value during Profile

Percent Signal Output

3

TOC11

N43:427

*

Output #3 SetĆOutput Value during Profile

Percent Signal Output

3

TOC12

N43:428

*

Output #4 SetĆOutput Value during Profile

Percent Signal Output

3

TOC17

N43:433

0

Output #1 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

4

TOC18

N43:434

0

Output #2 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

4

TOC19

N43:435

0

Output #3 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

4

TOC20

N43:436

0

Output #4 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

4

TOC25

N43:441

0

Output #1 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

4

TOC26

N43:442

0

Output #2 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

4

TOC27

N43:443

0

Output #3 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

4

TOC28

N43:444

0

Output #4 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

4

TOC33

N43:449

*

Output #1 SetĆOutput Value at EndĆof Profile

Percent Signal Output

3

TOC34

N43:450

*

Output #2 SetĆOutput Value at EndĆof Profile

Percent Signal Output

3

TOC35

N43:451

*

Output #3 SetĆOutput Value at EndĆof Profile

Percent Signal Output

3

TOC36

N43:452

*

Output #4 SetĆOutput Value at EndĆof Profile

Percent Signal Output

3

TOC41

N43:457

0

Pressure Minimum Control Limit

Pressure

2

TOC42

N43:458

*

Pressure Maximum Control Limit

Pressure

2

TOC43

N43:459

*

Selected Pressure Valve, Output for Minimum

Percent Signal Output

3

TOC44

N43:460

*

Selected Pressure Valve, Output for Maximum

Percent Signal Output

3

TOC45

N43:461

0

Velocity Minimum Control Limit

Velocity along Axis

5

TOC46

N43:462

*

Velocity Maximum Control Limit

Velocity along Axis

5

TOC47

N43:463

*

Selected Velocity Valve, Output for Minimum

Percent Signal Output

3

TOC48

N43:464

*

Selected Velocity Valve, Output for Maximum

Percent Signal Output

3

TOC49

N43:465

100

Proportional Gain for Pressure Control

None

TOC50

N43:466

400

Integral Gain for Pressure Control

Inverse Time (Algorithm)

6

TOC51

N43:467

0

Derivative Gain for Pressure Control

Time (Algorithm)

7

TOC52

N43:468

200

Proportional Gain for Velocity Control

Inverse Time (Algorithm)

6

TOC53

N43:469

0

Feed Forward Gain for Velocity Control

None

TOC57

N43:473

0

Profile High Pressure Alarm Setpoint

Pressure

2

1

Time

2

Pressure

3

Percent Signal Output

4

Percent Signal Output per Second

00.00 to 99.99 Seconds 0000 to 9999 PSI 00.00 to 99.99 0000 to 9999

000.0 to 999.9 Bar

5

Velocity along Axis

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent

00.00 to 99.99 Inches per Second 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99

000.0 to 999.9 Millimeters per Second 00.00 to 99.99 Seconds (AĆB) 00.00 to 99.99 Seconds (AĆB)

* Refer to the appropriate section later in this chapter for information on this parameter

Advertising