Jog your machine chapter 5 – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual
Page 64
Enter Your Initial Values Here
Jog Your Machine
Chapter 5
5-3
Worksheet 5. A
Ram (screw) and Clamp Jog Configuration Values
Control Block
Word
ProĆSet 600 Addr. Value
Description
Units
Inject, Forward Jog
JGC17
N40:73
Set Output Values Output #1
% Signal Output
1
JGC18
N40:74
Output #2
% Signal Output
1
JGC19
N40:75
Output #3
% Signal Output
1
JGC20
N40:76
Output #4
% Signal Output
1
Inject, Reverse Jog
JGC25
N40:81
Set Output Values Output #1
% Signal Output
1
JGC26
N40:82
Output #2
% Signal Output
1
JGC27
N40:83
Output #3
% Signal Output
1
JGC28
N40:84
Output #4
% Signal Output
1
Clamp, Forward Jog
JGC33
N40:89
Set Output Values Output #1
% Signal Output
1
JGC34
N40:90
Output #2
% Signal Output
1
JGC35
N40:91
Output #3
% Signal Output
1
JGC36
N40:92
Output #4
% Signal Output
1
Clamp, Reverse Jog
JGC41
N40:97
Set Output Values Output #1
% Signal Output
1
JGC42
N40:98
Output #2
% Signal Output
1
JGC43
N40:99
Output #3
% Signal Output
1
JGC44
N40:100
Output #4
% Signal Output
1
Jog Pressure Alarms
JGC06
N40:62
Ram Jog Pressure, Alarm Setpoint
Ram (screw) Pressure
2
JGC07
N40:63
Clamp Jog Pressure Alarm Setpoint
Clamp Pressure
2
1
% Signal Output
2
Pressure
00.00 to 99.99 %
0000 to 9999 PSI
000.0 to 999.9 Bar