Overview of Inject and Clamp Mode

Chapter 1

1-13

Figure 1.13

Example Clamp Open

Position

Velocity

1st Open

Profile

2nd Open

Profile

3rd Open

Profile

L

0

Clamp

Cylinder

Moving

Platen

Y

Stationary

Platen

You may start these operations between the three clamp open profiles:

drop the third plate of a mold (on a floating 3-plate mold) or pull cores
program other events for all valves
automatically bridge between profiles, or let ladder logic decide when to

begin the next profile.

Each of the clamp open profiles can be subdivided into three position
segments (Figure 1.14). You can change clamp velocity or pressure up to
three times in each profile, or up to nine times for the entire clamp open
phase.

Figure 1.14

Example Clamp Open Position Segments

Position

Velocity

3rd Open

Profile

2nd Open

Profile

1st Open

Profile

3

3

3

2

2

2

1

1

1

Segments

L

0

Clamp

Cylinder

Moving

Platen

Y

Stationary

Platen

Important: You may use as many or as few profiles and/or segments
within profiles as needed. If using a single open motion, use the first
segment of the 1st open profile. The open slow profile must follow.

After completing the last segment in each profile, the QDC module either
switches immediately to the next programmed segment of the next
programmed profile or waits for a command from your PLC-5 program to
continue.