10ć6 – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual

Page 214

Advertising
background image

Tune Your Machine

Chapter 10

10-6

General Guidelines for Velocity Tuning

If your machine will never run velocity profiles, skip this section.

In this section we present two procedures:

Tune Pressure Loops without an Oscilloscope
Tune Pressure Loops with an Oscilloscope

Repeat either one of these procedures as needed for tuning closed-loop
control of these velocity vs. position profiles:

Injection

1

Clamp Open (3)
Clamp Open Slow
Clamp Close (3)

1

Use the same gain constants for velocity and pressure-limited velocity.

Follow these general guidelines when tuning closed-loop velocity profiles:

Disable

ramping

Disable Expert Response Compensation (ERC)

Reset ERC values to zero by setting DYC05-B15 (B34/463) = 1.

(The QDC module resets this bit to zero after resetting ERC values.)

Important: Gain constants differ between velocity profiles. The dynamics
of loads being moved and different hydraulic characteristics warrant
separate PID tuning considerations for each profile.

Important: Never use feedforward gain and ERC in the same velocity
profile.

Important: In most cases, adding a feedforward term to the VelFF
algorithm makes it too sensitive and does not enhance loop stability.

Use proportional control with a zero feedforward term.

(Add feedforward only if required)

Use

the

highest

possible P gain constant for injection profiles

for precise performance without hammering your hydraulics.
but
Use the lowest possible P gain constant for clamp profiles
for repeatable performance.

Use an oscilloscope, if available. You can tune loops faster and easier

with it connected to QDC module’s output driving the selected valve.

Important: Skip to Tune Velocity Loops with an Oscilloscope, if you have
one.

Tune ClosedĆloop

Velocity Control

Advertising