Enter Your Initial Values Here

Configure the QDC Module's I/O

Chapter 3

3-5

Worksheet 3ĆD

Determine Initial SensorĆconfiguration Values

Input

Line

Control Word

ProĆSet 600 Addr. Value

Description

Units

1

1

MCC09

N40:5

0

Minimum Screw Position

Screw Axis Measured from zero

1

2

MCC10

N40:6

Maximum Screw Position

Screw Axis Measured from zero

1

3

MCC11

N40:7

Analog Signal @ Min Screw Position

Input Signal Range

2

4

MCC12

N40:8

Analog Signal @ Max Screw Position

Input Signal Range

2

2

5

MCC17

N40:13

0

Minimum Screw Pressure

Screw Pressure

3

6

MCC18

N40:14

Maximum Screw Pressure

Screw Pressure

3

7

MCC19

N40:15

Analog Signal @ Min Screw Pressure

Input Signal Range

2

8

MCC20

N40:16

Analog Signal @ Max Screw Pressure

Input Signal Range

2

3

9

MCC23

N40:19

0

Minimum Clamp Position

Clamp Axis Measured from zero

1

10

MCC24

N40:20

Maximum Clamp Position

Clamp Axis Measured from zero

1

11

MCC25

N40:21

Analog Signal @ Min Clamp Position

Input Signal Range

2

12

MCC26

N40.22

Analog Signal @ Max Clamp Position

Input Signal Range

2

4

13

MCC31

N40:27

0

Minimum Clamp Pressure

Clamp Pressure

3

14

MCC32

N40:28

Maximum Clamp Pressure

Clamp Pressure

3

15

MCC33

N40:29

Analog Signal @ Min Clamp Pressure

Input Signal Range

2

16

MCC34

N40:30

Analog Signal @ Max Clamp Pressure Input Signal Range

2

1

Incremental Distance

2

Input Signal Range

3

Pressure

00.00 to 99.99in 00.00 to 10.00VDC or

0000 to 9999 PSI

000.0 to 999.9mm 01.00 to 05.00VDC or 000.0 to 999.9 Bar

04.00 to 20.00MADC

Use this download procedure now and later in this chapter. The procedure
requires you to complete the following general steps:

enter MCC values into the PLC-5 data table
download them to the QDC module (PLC-5 processor in run mode)
correct any data entry (programming) errors

Next we describe the general steps:

Enter MCC Values into Your PLCĆ5 Data Table

With your programming terminal, enter values from Worksheet 3-A thru
Worksheet 3-D into your PLC-5 data table as follows:

1. Switch the PLC-5 processor to program mode.

2. Display your PLC-5 data table.

3. Locate the data file for storing the MCC block. PLC-5 data table

word addresses are listed on the worksheets.

Download MCC Values

to the QDC Module