Counter: c01 – c32 – Rockwell Automation 1760-DNET Pico DeviceNet Communications Module User Manual User Manual

Page 110

Advertising
background image

Publication 1760-UM003A-EN-P - September 2005

7-30 Pico GFX Control Commands

Counter: C01 – C32

01

OR Or

sequence

02

XOR

Exclusive Or sequence

03

NET

Inverts the individual bits of the value at I1. The inverted
value is represented as a signed decimal value.

Table 6.119 Telegram Structure

Byte

Meaning

Value (hex), sent by

Master Slave

Master

Slave

Attribute ID

Read

92

Write

B2

0

Response:

Read successful

C2

Write successful

C1

Command rejected

C0

0

1

Type

14

14

1

2

Instance

01 – 20

01 – 20

2

3

Index

Table 6.120

Table 6.120

3 – 6

4 – 7

Data 1 – 4

Read operation

00

depending on
index,Table 6.121

Write operation

depending on
index,Table 6.121

00

Table 6.120 Operand overview

Index
(hex)

Operand

Value

read

write

00

Bit IO

Table 6.121

x

01

Mode/Parameter

Table 6.118 Index 1 - Mode

Data 1
(hex)