7-60 Pico GFX Control Commands
Set cycle time function block: ST01
(1) Trigger coil. If the coil is triggered (rising edge), the current date, weekday and time of the sending station are
automatically sent to the NET network.
(2) Status 1 if the trigger coil SC01T_ is also 1.
Table 6.187 Telegram Structure
Byte
Meaning
Value (hex), sent by
Master Slave
Master
Slave
Attribute ID
Read
92
–
Write
B2
–
0
Response:
Read successful
–
C2
Write successful
–
C1
Command rejected
–
C0
0
1
Type
2C
2C
1
2
Instance
01
01
2
3
Index
Table 6.188
Table 6.188
3 – 6
4 – 7
Data 1 – 4
Read operation
00
depending on
index,Table 6.189
Write operation
depending on
index,Table 6.189
00
Table 6.188 Operand overview
Index
(hex)
Operand
read
write
00
Bit IO, Table 6.189
x
01
Mode/Parameter
–
–
02
Cycle time in ms,
value range: 0 – 1000
I1
x
c
(1)
(1) The value can only be written if it is assigned to a constant in the program.