Publication 1760-UM003A-EN-P - September 2005

6-6 Application Examples for Pico

Counters: C1 to C16

The following commands are used to read the logic state of the
individual counters C1 to C16.

Table 6.8 Byte 3 to 4 (master) or Byte 4 to 5 (slave): Data 1 to 2

Data
1

Bit

7

6

5

4

3

2

1

0

A1

0/1

A2

0/1

...

...

A8

0/1

Data
2

Bit

7

6

5

4

3

2

1

0

A9

0/1

A10

0/1

...

...

A16

0/1

Table 6.9 Telegram Structure

Byte

Meaning

Value (hex) sent by

Master

Slave

Master

Slave

Attribute ID:
Read

88

-

0

Response:

Read
Successful

-

C2

Command
Rejected

-

CO

(1)

(1)

Possible causes page 6-34

0

1

Len

01

01

1

2

Type

EE

EE

2

3

Index

00

00

3

4

Data 1 (Low
Byte)

00

Table 6.10

4

5

Data 2 (Low
Byte)

00

Table 6.10

5 to 6

6 to 7

Data 3 to 4

00

00