Operating hours counters: o1 – o4 – Rockwell Automation 1760-DNET Pico DeviceNet Communications Module User Manual User Manual
Page 69
Advertising
![background image](/manuals/579693/69/background.png)
Publication 1760-UM003A-EN-P - September 2005
Application Examples for Pico 6-25
Explanation:
Data 1 = 12
Data 2 = 03
l resulting 16-bit value = 0312
hex
= 786
dec
Counter status = 786
Operating hours counters: O1 – O4
Table 6.47 C3 Value to Read
Byte
Meaning
Value (hex), sent by
Master
Slave
Master
Slave
Command: Read
89
–
0
Response: read successful
–
C2
0
1
Type
8F
8F
1
2
Instance
02
02
2
3
Index
02
02
3
4
Data1
00
12
4
5
Data 2
00
03
5
6
Data 3
00
00
6
7
Data 4
00
00
Table 6.48 Telegram Structure
Byte
Meaning
Value (hex), sent by
Master Slave
Master
Slave
Attribute ID
Read
89
–
Write
8D
–
0
Response:
Read successful
–
C2
Write successful
–
C1
Command rejected
–
C0
(2)
0
1
Type
92
92