Pico GFX Control Commands 7-5

Switching rule bit array

Table 6.71 Index 01 – Summer/Winter time switchover

Byte

Content

Value (hex)

Master

Slave

2

3

Data 1

Area

None

00

Manual

01

Automatic EU

02

Automatic GB

03

Automatic US

04

Rule

(1)

(1) Detailed setting possibilities for Pico GFX from version 05

05

for “Area” = “manual”:

3

4

Data 2

Set summer time day (1 to 28,
29, 30, 31 depending on month
and year).

00 – 3B

4

5

Data 3

Set Summer time month (1 to 12) 01 – 1F

5

6

Data 4

Set winter time day (
1 to 28, 29, 30, 31
depending on month and year)

01 – 0C

6

7

Data 5

Set Winter time month (1 to 12)

00 – 63

for “Area” = “Rule”

(1)

:

3 – 6

4 – 7

Data 2 – 5

Summer time switching rule

Table 6.73

Table 6.72 Index 02 – Winter time (only valid if Area = “Rule” selected)

Byte

Content

Value (hex)

Master

Slave

2

3

Data 1

Area = Rule

01

3 – 6

4 – 7

Data 2 – 5

Winter time switching rule

Table 6.73

TIP

Refer to 1760-UM002 for more information. The
following table shows the composition of the
corresponding data bytes.

Advertising