Rockwell Automation 1760-DNET Pico DeviceNet Communications Module User Manual User Manual
Page 85

Publication 1760-UM003A-EN-P - September 2005
Pico GFX Control Commands 7-5
Switching rule bit array
Table 6.71 Index 01 – Summer/Winter time switchover
Byte
Content
Value (hex)
Master
Slave
2
3
Data 1
Area
None
00
Manual
01
Automatic EU
02
Automatic GB
03
Automatic US
04
Rule
(1)
(1) Detailed setting possibilities for Pico GFX from version 05
05
for “Area” = “manual”:
3
4
Data 2
Set summer time day (1 to 28,
29, 30, 31 depending on month
and year).
00 – 3B
4
5
Data 3
Set Summer time month (1 to 12) 01 – 1F
5
6
Data 4
Set winter time day (
1 to 28, 29, 30, 31
depending on month and year)
01 – 0C
6
7
Data 5
Set Winter time month (1 to 12)
00 – 63
for “Area” = “Rule”
(1)
:
3 – 6
4 – 7
Data 2 – 5
Summer time switching rule
Table 6.73
Table 6.72 Index 02 – Winter time (only valid if Area = “Rule” selected)
Byte
Content
Value (hex)
Master
Slave
2
3
Data 1
Area = Rule
01
3 – 6
4 – 7
Data 2 – 5
Winter time switching rule
Table 6.73
TIP
Refer to 1760-UM002 for more information. The
following table shows the composition of the
corresponding data bytes.