Publication 1760-UM003A-EN-P - September 2005

Application Examples for Pico 6-31

Example:

Data 1 (Byte 4) = 0x03

l The values for the year time switch of

channels A and B appear in the parameter menu.

Channel A, index 11/12

Index 0x11 channel A timepoint of switch on

Index 0x12 channel A timepoint of switch off

Data 1 (Byte 4) – day

Data 2 (Byte 5) – month

Data 3 (Byte 6) – year

Example:

The year time switch channel A should be switched on at the
21.04.2004.

Channel D

x

c

(1)

41

Time point ON

x

c

(1)

42

Time point OFF

x

c

(1)

(1) The value can only be written if it is assigned to a constant in the program.

In the data bytes Data 1 – Data 3 the switching points are transferred.

Table 6.60 Index 00 – Parameters

Meaning

Bit

7

6

5

4

3

2

1

0

Appears in the
parameter menu

Channel A

0/1

Channel B

0/1

Channel C

0/1

Channel D

0/1

Unused bits

Table 6.61 Index 01 – Control byte

Data 1

Bit

7

6

5

4

3

2

1

0

FB output

Q1

(1)

(1) Status 1 if count condition is fulfilled.

Table 6.59 Operand overview

Index
(hex)

Operand

Read

Write