Operating hours counters: o1 – o4 – Rockwell Automation 1760-DNET Pico DeviceNet Communications Module User Manual User Manual
Page 57

Publication 1760-UM003A-EN-P - September 2005
Application Examples for Pico 6-13
The markers N3, N11 and N16 are set.
Operating hours counters: O1 – O4
The following commands are used to read the logic state of the
operating hours counters O1 – O4.
Table 6.21 The N Markers are Read
Byte
Meaning
Value (hex), sent by
Master
Slave
Master
Slave
Attribute ID: Read
88
–
0
Response:
Read successful
–
C2
Command rejected
–
C0
(1)
(1) Possible causes <bullets>a page 49
0
1
Len
01
01
1
2
Type
N marker
87
87
2
3
Index
00
00
3
4
Data 1 (Low Byte)
00
04
4
5
Data 2 (Low Byte)
00
84
5 – 6
6 – 7
Data 3 – 4
00
00
Table 6.22 Telegram Structure
Byte
Meaning
Value (hex), sent by
Master
Slave
Master
Slave
Attribute ID: Read
88
–
0
Response:
Read successful
–
C2
Command rejected
–
C0
(1)
(1) Possible causes page 6-34
0
1
Len
01
01
1
2
Type
EF
EF
2
3
Index
00
00
3
4
Data 1 (Low Byte)
00
4 – 6
5 – 7
Data 2 – 4
00
00