Hours-run meters: ot01 – ot04 – Rockwell Automation 1760-DNET Pico DeviceNet Communications Module User Manual User Manual
Page 135
![background image](/manuals/579693/135/background.png)
Publication 1760-UM003A-EN-P - September 2005
Pico GFX Control Commands 7-55
Hours-run meters: OT01 – OT04
Telegram structure
Table 6.174 Index 1 - Mode
Data 1
(hex)
00
BCD
Converts a BCD coded decimal value to an integer value.
01
BIN
Converts an integer value to a BCD coded decimal value.
h
Further information is available in the S40 Application
Note AN27K21g.exe “Pico GFX-DP Data Handling
Function Block for PS416 and PS4-341”.
Table 6.175 Telegram Structure
Byte
Meaning
Value (hex), sent by
Master Slave
Master
Slave
Attribute ID
Read
92
–
Write
B2
–
0
Response:
Read successful
–
C2
Write successful
–
C1
Command rejected
–
C0
0
1
Type
1E
1E
1
2
Instance
01 – 04
01 – 04
2
3
Index
Table 6.176
Table 6.176
3 – 6
4 – 7
Data 1 – 4
Read operation
00
depending on
index,Table 6.177
Write operation
depending on index,
Table 6.177
00