Local outputs: q1 – q8 – Rockwell Automation 1760-DNET Pico DeviceNet Communications Module User Manual User Manual
Page 59
Advertising
![background image](/manuals/579693/59/background.png)
Publication 1760-UM003A-EN-P - September 2005
Application Examples for Pico 6-15
Example:
Data 1 = 2
hex
l P3 is active.
Local outputs: Q1 – Q8
The local outputs can be read directly via the DeviceNet fieldbus.
Table 6.25 Byte 3 (master) or byte 4 (slave): Data 1
Data 1
Bit
7
6
5
4
3
2
1
0
P1
0/1
P2
0/1
P3
0/1
P4
0/1
–
0
–
0
–
0
–
0
Table 6.26 Telegram Structure
Byte
Meaning
Value (hex), sent by
Master
Slave
Master
Slave
Attribute ID: Read
88
–
0
Response:
Read successful
–
C2
Command rejected
–
C0
(1)
(1) Possible causespage 6-34
0
1
Len
01
01
1
2
Type
85
85
2
3
Index
00
00
3
4
Data 1 (Low Byte)
00
4 – 6
5 – 7
Data 2 – 4
00
00
Table 6.27 Byte 4: Data 1
Data 1
Bit
7
6
5
4
3
2
1
0
Q1
0/1
Advertising